Youshan Electromechanical Engineering+86 18201786105

Troubleshooting Preload Loss

Check installed height, contact surfaces and service conditions before replacing a spring.

Record the issue as it occurs

Document whether the change appeared at assembly, after thermal cycling or after a number of operating cycles. Record measured working height, force or joint behavior, and compare them with the initial values.

Check the stack and interfaces

Verify part number, disc count and orientation, support faces, available stroke and guide clearance. Inspect for uneven contact, wear, corrosion or damage. For valve and flange assemblies, include packing or gasket changes in the investigation.

Send comparable measurements

Collect a drawing, part photographs, operating temperatures and the original and current load–height values. Measure at the same heights on a known-good part if available. This information helps distinguish an assembly change from a spring change.

Discuss your spring requirements

Share your drawing, dimensions or service conditions with our team.

Contact Sales